Breaking Load Table

 

Nominal Diameter

Approximate Mass

Minimum breaking loads - 1770 Mpa

Minimum breaking loads - 1960 Mpa

[mm]

[kg/m]

[kN]

[Kg]

[kN]

[Kg]

8

0.235

37.38

3,813

41.40

4,222

9

0.297

47.31

4,825

52.39

5,343

10

0.367

58.41

5,957

64.68

6,597

11

0.444

70.68

7,208

78.26

7,982

12

0.528

84.11

8,579

93.14

9,500

14

0.719

114.48

11,677

126.77

12,930

16

0.940

149.53

15,252

165.58

16,889

18

1.189

189.25

19,303

209.56

21,375

20

1.468

233.64

23,831

258.72

26,389

22

1.776

282.70

28,835

313.05

31,931

24

2.114

336.44

34,317

372.56

38,000

26

2.481

394.85

40,274

437.24

44,598

28

2.877

457.93

46,709

507.09

51,723

30

3.303

525.69

53,620

582.12

59,376

32

3.758

598.12

61,008

662.32

67,556

34

4.243

675.22

68,872

747.70

76,265

36

4.756

756.99

77,213

838.25

85,501

38

5.299

843.44

86,030

933.98

95,265

40

5.872

934.56

95,325

1034.88

105,557

42

6.474

1030.35

105,095

1140.96

116,377

44

7.105

1130.82

115,343

1252.20

127,724

46

7.766

1235.96

126,067

1368.63

139,600

48

8.456

1345.77

137,268

1490.23

152,003

50

9.175

1460.25

148,945

1617.00

164,934

52

9.924

1579.41

161,099

1748.95

178,392

56

11.509

1831.74

186,837

2028.36

206,893

60

13.212

2102.76

214,481

2328.48

237,504